Eleaf ASTER RT User Manual

Eleaf ASTER RT

How to Use?
Power on/off: Press the fire button 5 times in quick succession to turn on/off the device. Keep holding the fire button to take a puff when the device is powered on.

Stealth on/off: Press the fire button and down button simultaneously when the device is powered on to switch between Stealth On and Stealth Off mode. In Stealth On mode, you can vape with the OLED screen off and you can press the fire button one time to see current setting.

Adjustment buttons lock/unlock: Keep pressing up button and down button simultaneously for two seconds when the device is powered on, then the up and down buttons will be locked and the screen will display “Key Lock”. In the same way, the up and down buttons can be unlocked and the screen will display “Key Unlock”. Through this operation, you can protect the buttons from unintentional presses and prolong their lifespan. 

Switch display mode: Keep pressing up button and down button simultaneously for two seconds when the device is powered off, the screen display will rotate 180 degrees. You can view the screen from two different angles through this operation. 

Switch display interfaces: In power-on state, choose VW mode; keep holding up and fire buttons till the current interface flashes; when it’s flashing, press up or down button to switch among different interfaces; finally press fire button once to confirm the interface you chose. 

Note: the interfaces can only be changed and selected under VW mode in power-on state. And when one interface is selected under VW mode, the interface of Bypass and TC (Ni, Ti, SS, M1, M2, M3) modes will change accordingly and automatically.

Preheat function: In power-off state, keep holding up button and fire button till the M1 mode appears; press the fire button 3 times to “Pwr”, and press up or down button to adjust the wattage of preheat; press the fire button again to “Time”, and press up or down button to adjust the second of preheat or to turn off the preheat function. 

Switch vaping modes: When the device is powered on, press the fire button 3 times in quick succession, the device will display current vaping mode. Press the up or down button to switch among VW, Bypass, Smart, TC-Ni, TC-Ti, TC-SS, TCR-M1, TCR-M2, TCR-M3 modes and then press the fire button one time or stay in the interface for about 10 seconds to confirm the vaping mode you chose. 

1) VW mode: When set in VW mode, the device can support a coil whose resistance is within the range of 0.1ohm-3.5ohm. 

Adjust wattage: In this mode, the output wattage can be adjusted from 1W to 100W by pressing up button or down button, up button to increase and down button to decrease. Long press up button or down button can rapidly increase or decrease the wattage level.

2) Bypass mode: When set in Bypass mode, the device can support a coil whose resistance is within the range of 0.1ohm-3.5ohm. Direct output voltage system is applied in this mode. The higher the battery level is, the higher the output voltage will be. 

3) Smart mode: The Smart mode will save one output power setting for each resistance value and can totally save ten groups of such settings. Once you change the output power setting for a resistance, it will re-save the changed setting automatically. When the Smart mode has already remembered ten settings and you want to add another new resistance, the first saved setting will be deleted. 

4) TC-Ni/TC-Ti/TC-SS/TCR(M1, M2, M3) Mode: When set in TC-Ni/TC-Ti/TC-SS mode, the device can separately support Nickel 200, Titanium, and Stainless Steel 316 coils. In TCR (Temperature Coefficient of Resistance) mode, the device can support different temperature control coils within different TCR value ranges and you can set the TCR at different values within proper range. (Resistance range of coil: 0.05ohm-1.5ohm)
The Setting of TCR Mode (M1,M2,M3): When the device is powered off, keep pressing the fire button and the up button simultaneously, then you will enter into the TCR (M1,M2,M3) set menu: 
1. Press fire button to choose among M1, M2 and M3 modes; 
2. Press the up or down button to increase or decrease the TCR value according to the material of the coil you use; 
3. Keep pressing the fire button or stay in the interface for about 10 seconds to confirm your setting. 

Following are different TCR value ranges for different coils for your reference:
Adjust wattage: In TC-Ni/TC-Ti/TC-SS/TCR(M1,M2,M3) mode, the output wattage can be adjusted from 1W to 100W. Press the fire button 4 times in quick succession to enter the wattage setting menu and press up or down button to increase or decrease the wattage level. Keep pressing up or down button without looseness to rapidly increase or decrease the wattage level. 

Adjust temperature: In TC-Ni/TC-Ti/TC-SS/TCR(M1,M2,M3) mode, temperature can be adjusted from 100-315℃ or 200-600℉ by pressing up or down button, up button to increase and down button to decrease. Each press of the up or down button will increase or decrease the temperature setting by 5℃ or 10℉. Keep pressing up or down button without looseness can rapidly increase or decrease temperature setting. 

Shift between ℃ and ℉: If you increase the temperature to 315 ℃, and continue to press the up button, the temperature reading will automatically change to the lowest Fahrenheit (200℉). Equally, if the temperature is set at the lowest Fahrenheit (200℉) and you continue to press the down button, the temperature reading will automatically change to the highest Celsius (315 ℃). 

Lock/Unlock resistance: In TC-Ni/TC-Ti/TC-SS/TCR(M1,M2,M3) mode, when the device is powered on, keep pressing the fire button and up button simultaneously for two seconds to lock or unlock atomizer “base resistance”. The lock sign will appear when resistance is locked and “Ω” symbol will come back when unlocked. 

Note: 
1. Please lock the resistance when the coil is at room temperature so that the device can display the correct “base resistance”.
2. In resistance lock mode, when you remove the coil and then put it back, the device can maintain the same “base resistance” although the coil resistance may increase due to the rise of temperature. In resistance unlock mode, when you remove the coil and then put a coil back, the screen may display “New coil up same down” as the coil resistance may increase within certain range. If it is the same coil, press the down button and if it is a new coil, press the up button. But please unlock the resistance when you want to change an atomizer or a coil of different resistance. 

3. When using a common coil or a coil whose resistance is above 1.5ohm in TC-Ni/TC-Ti/TC-SS/TCR(M1,M2,M3) mode by mistake, the device will automatically switch back to VW mode. 

How to put custom logo in the Eleaf ASTER RT? 
Download the file on our official website, plug the device in with USB cable to a computer, and double click the EleafUpdate.exe. Then click “LOGO” and open the image you choose to put it in the device. Finally press the fire button twice in quick succession when the device is powered on to enter logo on/off interface and press up or down button one time to turn on/off logo. 
Note: 
1. Please make sure the image you choose is a monochrome image of 64*32 pixels in the format of bmp. 
2. If you fail to put the custom logo in and the device shuts down, press the down button once to restart the device. 

Properties 
Atomizer Protection: Each time when vaping time exceeds 10 seconds, the output shuts off automatically with “Over 10s Protection” display on the screen. 

Atomizer Short-circuit & No Atomizer Protection: When atomizer short-circuit occurs, the OLED screen will display “Atomizer Short”. The screen will display “No Atomizer” when there is no atomizer connected. 

Low-voltage Protection: When the voltage of the device is below 3.3V, the OLED screen will display “Lock” and the output will cut off automatically. Charge the device to reactivate it. 

Temperature Protection: In TC-Ni/TC-Ti/TC-SS/TCR(M1,M2,M3) mode, when the actual temperature of coil reaches the set temperature, the screen will display "Temp Protection". 

Temperature Alert: If the temperature of device is over alert temperature, the output will shut off automatically and the screen will display “Device Too Hot”. You can continue to vape after it cools down. 